Top
Power Supplies
Power Supplies

GK-180-24-E-N open frame - IEC

GK-180-24-E-N open frame – IEC
GENERAL DESCRIPTION

The Gicar Power Supplies meet specific market needs: always more efficient, with smaller sizes and in compliance with the latest regulations regarding energy saving and related to the consumption in stand-by mode.

SAFETY STANDARD:
IEC 60335-1

In addition to the IEC 60335-1 standard, this product also complies with the UL/IEC 60950-1 and UL/IEC 62368-1 standard

AC nominal input: 200-240 Vac
DC nominal output: 24 Vdc
Protections: Short circuit/Overload/Open circuit
High efficiency (up to 92% at full load)
Resonant Topology
Low EMI emission
“Power On” LED
Electrolytic capacitors: 105 °C long life
Operating temperature: up to 60 °C
Long life and high reliability
OUTPUTOUTPUT POWER180 W
DC VOLTAGE24 V
RATED CURRENT7.5 A
CURRENT RANGE0-7.5 A
RIPPLE (note 2)450 mVpp max
VOLTAGE TOLERANCE (note 3)±5%
LINE REGULATION (note 4)±3%
LOAD REGULATION (note 5)±3%
SETUP, RISE TIME (note 6)500 ms, 80 ms
HOLD UP TIME (typ)100 ms
INPUTVOLTAGE RANGE200-240 Vac
FREQUENCY RANGE50-60 Hz
EFFICIENCY92% (@ full load)
AC CURRENT1.54 A max
PROTECTIONOVERLOAD - INRUSHMax inrush current on load: 18 A for 150 ms
SHORT CIRCUITProtection type: Hiccup mode, recovers automatically after fault condition is
removed
ENVIRONMENTWORKING TEMP0 to 60 °C (refer to derating curve)
POLLUTION DEGREEII
SAFETY & EMCSAFETY STANDARDIEC 60335-1
WITHSTAND VOLTAGEInput to Output: 3 K Vac
EMC EMISSIONEN 55014-1, EN 61000-3-2, EN 61000-3-3
EMC IMMUNITYEN 55014-2 (EN 61000-4-2, -4, -5, -6, -11)
OTHERSDIMENSION120x100x50 mm (LxDxH)
IN/OUT CONNECTIONS5 mm pitch Screw connector
FIXING4 non-conductive plastics spacers
NOTES1.All parameters NOT specially mentioned are measured at 230 Vac input, rated load and 25 °C ambient temperature
2.Ripple & noise are measured at 20 MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1 uF & 47 uF parallel capacitor
3.Tolerance: total tolerance of output voltage measured at 230 Vac input and 50% of rated power
4.Line regulation is measured from low line (200 Vac) to high line (240 Vac) at rated load (160/180 W)
5.Load regulation is measured from 0% to 100% of rated load at 230 Vac
6.Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase the setup time

SWITCHING POWER SUPPLIES 180W

200-240 VAC
GK-180-24-E-N
IECEE CB SCHEME
Certificate No. NO106073
Note Note:
  • Do not use the Power supply outside of Safe Operating Area, internal parts may occasionally deteriorate or can be damaged.
  • If the power is not reduced when Tamb is above 50 °C the device will run into thermal protection so the output will shut-off voltage output (Hiccup mode) until ambient temperature or load is reduced as far as necessary to keep device in working condition.
Important note Important note:

The label provided with the product must be applied near the power supply in final installation